1 Alarms
14114
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14115
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14116
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14117
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14118
Parameters:
1-190
Channel %1 block %2 programmed tilt angle too large
%1 = Channel number
%2 = Block number, label
No further explanation.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal definition of workpiece surface
%1 = Channel number
%2 = Block number, label
The surface normal vectors programmed at the beginning of block and at the end of block
point in opposite directions.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 absolute orientation programmed while ORIPATH is active
%1 = Channel number
%2 = Block number, label
The orientation has been entered as an absolute value (e.g. by a direction vector)
although ORIPATH is active. When ORIPATH is active, the orientation is determined from
the leading and sidewards angles relative to the path tangent and surface normal.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no angle or direction of the cone programmmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation (ORICONCW and ORICONCC),
either the opening angle or the direction vector of the taper must be programmed. Other-
wise, the change of orientation is not clearly defined.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no end orientation programmed
%1 = Channel number
%2 = Block number, label