10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
61413
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61414
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61415
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61416
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
The alarm is triggered by the following cycles: CYCLE997, CYCLE119
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Set MD 28081>0, $P_CHBFRMASK>0
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Check setpoint value of spherical diameter, _SETVAL <=0
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE997
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check setpoint value of spherical diameter.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Distortion of the triangle exceeds the limit
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE997, CYCLE119
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check the setpoint and actual values
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Check probe/machining plane
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE971
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Enter permissible probe (_TP[x,8], _TPW[x,8]) for machining plane or change machining
plane.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Adjust field size %4!
%1 = Channel number
%2 = Block number, label channel number
Channel %1 block %2 'Adjust field size _TP[ ]/_CVAL[0]!' or 'Adjust field size _WP[ ]/
_CVAL[1]!' or 'Adjust field size _KP[ ]/_CVAL[2]!' or 'Adjust field size _TWP[ ]/_CVAL[3]!'
Check probe/machining plane
1 Alarms
1-459