1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
20062
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20063
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20065
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-318
The axis is not an orientation axis and can therefore not be traversed as an orientation
axis in JOG mode.
- Alarm display.
Register the axis as an orientation axis.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 already active
%1 = Channel number
%2 = Axis name, spindle number
The displayed axis is already traversing as a machine axis. Therefore, it cannot be oper-
ated as a geometry axis.
Traversing of an axis can take place in JOG mode through 2 different interfaces.
1. as a geometry axis: via the channel-specific interface DB 21 - DB 28, DBX12.6 or
DBX12.7
2. as a machine axis: via the axis-specific interface DB 31 - DB 48 DBX8.6 or DBX8.7
With the standard machine control panel, it is not possible to operate an axis as machine
axis and geometry axis at the same time.
- Alarm display.
Do not start the geometry axis until the traversing motion as machine axis has been con-
cluded.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 orientation axes cannot be traversed without transformation
%1 = Channel number
%2 = Axis name
An attempt was made to move an orientation axis in JOG mode without an active orienta-
tion transformation.
- Alarm display.
Activate an orientation transformation.
Clear alarm with the Delete key or NC START.
Channel %1 master spindle not defined for geometry axes in JOG mode
%1 = Channel number
The displayed axis is to be traversed as geometry axis in JOG mode with rotary feed, but
no master spindle has been defined from which the actual speed could be derived.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
If the revolutional feed is also to be active in JOG mode, then a master spindle must be
declared via the channel-specific machine data 20090 SPIND_DEF_MASTER_SPIND. In
this case you have to open a screen in the PARAMETER operating area with the softkeys
"SETTINGDATA" and "JOG DATA" and preselect the G function G95 there. The JOG fee-
drate can then be entered in [mm/rev]. (If 0 mm/rev is set as JOG feed, the control takes
the value assigned in the axis-specific MD 32050 JOG_REV_VELO or in the case of rapid
traverse overlay 32040 JOG_REV_VELO_RAPID).
The revolutional feed in JOG mode is deactivated by changing the G function from G95 to
G94.
Clear alarm with the Delete key or NC START.