Siemens SINUMERIK 840D Diagnostics Manual page 239

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
15172
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15175
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15180
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15185
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Perform another precompilation.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 subroutine %3. No interface available at time of preprocess-
ing.
%1 = Channel number
%2 = Block number, label
%3 = Subroutine name
In compilation mode no program interface of the subroutine to be called was available at
the time of pre-compilation.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify parts program or recreate program interfaces and pre-compile programs again.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 program %3. Interfaces could not be built
%1 = Channel number
%2 = Block number, label
%3 = String
An error has occurred in interface generation mode. The (compiler) error message refers
to the program specified here. In particular when loading new cycle program on the NCK,
problems can occur if the value settings in machine data
$MN_MM_NUM_MAX_FUNC_NAMES and $MN_MM_NUM_MAX_FUNC_PARAM are
too small.
- Alarm display.
• Modify part program.
• If new cycle programs have been loaded on the NCK, you will normally need to increase
the values of $MN_MM_NUM_MAX_FUNC_NAMES and
$MN_MM_NUM_MAX_FUNC_PARAM. See also the explanations for alarm 6010.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 program %3 could not be edited as INI/DEF file
%1 = Channel number
%2 = Block number, label
%3 = String
Errors were found when processing an initialization program (INI file), or a GUD or macro
definition file (DEF file).
The error message which is then displayed refers to the program specified here.
- Alarm display.
Correct the initialization program (INI file), or the GUD or macro definition file (DEF file).
In connection with Alarm 12380 or 12460, also change the memory configuration.
Clear alarm with the Delete key or NC START.
Channel %1 %2 errors in INI file
%1 = Channel number
%2 = Number of detected errors
1 Alarms