10.04
61369
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61370
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61371
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61372
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 Position of corner not clearly definable, check parameter
_SETV[0...7]
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE961.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Define P1 and P2 or P3 and P4 in a way that the intersection of the straights determined
by these points is outside the sections formed by P1 and P2 or P3 and P4.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 _PROTVAL[0] - _PROTVAL[5] do not have any entries
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE105.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Enter values in _PROTVAL[0...5].
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 The log of column width and number of columns exceeds 200
characters per line
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE105.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Reduce the column width or number of columns.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Selected measuring variant requires SPOS-capable spindle
%1 = Channel number
%2 = Block number, label channel number
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Change measuring variant or check machine equipment.
Clear alarm with the RESET key. Restart part program
1 Alarms
1-455