1 Alarms
100106
Definitions:
Reactions:
Remedy:
Program Continuation:
100300
Definitions:
Remedy:
Program Continuation:
100301
Definitions:
Remedy:
Program Continuation:
100302
Definitions:
Remedy:
Program Continuation:
100303
Definitions:
Remedy:
Program Continuation:
100350
Definitions:
Remedy:
Program Continuation:
100351
Definitions:
Remedy:
Program Continuation:
1-488
Error on saving
This message will be displayed on editing a file (part program), if a memory operation
could not be performed correctly.
- Alarm display.
If there is no memory space left in the NCK, it will not be possible to save anything. Other
contents (files, programs) must be deleted.
If the error occurs when the program is started immediately after the change, the changes
will not become effective. The program should be stopped immediately. The change must
be repeated and the program must be started after a small delay (approx. 1 sec.).
If the error occurs when a program is changed during execution, only a program reset will
help.
Internal
xxx not found
The search term entered in a list image (e.g. general machine data) was not found.
--
Internal
The table cannot be completely generated
The list image could not be generated due to insufficient memory.
System error, a rebooting may be necessary.
Internal
No data available - or no access authorization
The list image can not be generated, as this data is currently not available. Example:
Local user data is not defined.
--
Internal
Paging not possible
You cannot page over, for example, axes, drives or channels, as more axes, drives or
channels are not configured.
--
Internal
Display MD saved
• The display machine data is saved via the softkey "Save" in the operating area start-up,
image machine data - display machine data.
• The display machine data is saved in the start-up basic display after pressing the softkey
"LCD brighter" or "LCD darker" (this setting will remain at the next start-up).
• As of SW 4.1: If the display options are changed in the machine data images, the
change will be saved in the display machine data that is not visible to the user.
--
Internal
Display MD take-over not possible
Saving the display machine data was rejected by the NCK.
--
Switch control OFF - ON.