1 Alarms
Reactions:
Remedy:
Program Continuation:
300951
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300952
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301701
Parameters:
1-614
- Alarm display.
Please inform the authorized personnel/service department. If no safe automatic refer-
encing is possible, the user must confirm the new position via the softkey. This user con-
firmation marks this position as safe, that means the axis status "Axis safely referenced"
is reached.
Warning:
If the axis has not been safely referenced and the user has not confirmed, the following
applies:
• The safe cams are still active and not yet safe.
• The safe limit positions are not yet active.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 test stop is running
%1 = Axis number
%2 = Drive number
The pulses are deleted.
1. If the positive acknowledgement is not received within the time configured in MD 1357:
$MD_SAFE_PULSE_DIS_CHECK_TIME (time for checking the pulse deletion), STOP A
is triggered.
2. If pulse deletion is acknowledged within the configured time in the drive, no stop reac-
tion is triggered. This message will be displayed during selection via the SGE "Test stop
selection" until the selection is canceled.The test stop has been activated by the user by
setting the SGE "Test stop selection". If the user cancels the SGE "Test stop selection",
the message will also be cancelled.
Request: In monitoring cycle.
The test stop has been activated by the user by setting the SGE "Test stop selection". The
pulses are deleted.
1. If the positive acknowledgement is not received within the time configured in MD 1357:
$MD_SAFE_PULSE_DIS_CHECK_TIME (time for checking the pulse deletion), STOP A
is triggered.
2. If pulse deletion is acknowledged within the configured time in the drive, no stop reac-
tion is triggered. This message will be displayed during selection via the SGE "Test stop
selection" until the selection is canceled.
- Alarm display.
The message disappears automatically if the test is terminated by the user by clearing the
SGE "Test stop selection". If STOP A is triggered, restart is only possible with POWER
ON.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 acceptance test is active
%1 = Axis number
%2 = Drive number
The acceptance test has been activated by the user.
- Alarm display.
This message disappears automatically when the test is finished.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 limit value for safe velocity too large
%1 = Axis number
%2 = Drive number
 Siemens AG, 2004. All rights reserved