1 Alarms
61109
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61110
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61111
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61112
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-422
Channel %1 block %2 parameter _CDIR incorrectly defined
%1 = Channel number
%2 = Block number, label
The value of the parameter for the cutting direction _CDIR has been incorrectly defined.
Alarm triggered by following cycles: POCKET3, POCKET4.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Modify parameter.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 finishing allowance at the base > depth infeed
%1 = Channel number
%2 = Block number, label
The finishing allowance at the base has been specified greater than the maximum depth
infeed. Alarm triggered by following cycles: POCKET3, POCKET4.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Either reduce finishing allowance or increase depth infeed.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 infeed width > tool diameter
%1 = Channel number
%2 = Block number, label
The programmed infeed width is greater than the diameter of the active tool. Alarm trig-
gered by following cycles: CYCLE71, POCKET3, POCKET4.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Infeed width must be reduced.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 tool radius negative
%1 = Channel number
%2 = Block number, label
The radius of the active tool is negative. This is illegal. Alarm triggered by following cycles:
CYCLE72, CYCLE76, CYCLE77, CYCLE90.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
--
Clear alarm with the RESET key. Restart part program