10.04
14138
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14139
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14140
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14144
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 Polynomials PO[XH], PO[YH] and PO[ZH] are not permitted
%1 = Channel number
%2 = Block number, label
Polynomials for the coordinates of a reference point on the tool (PO[XH], PO[YH],
PO[ZH]) can only be programmed, if interpolation type ORICURVE is active. If ORIVECT,
ORIPLANE, ORICONxxx is active, no polynomials can be programmed for coordinates
XH, YH and ZH.
- Correction block is reorganized.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Modify the NC program
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 Polynomial for angle of rotation PO[THT] is not permitted
%1 = Channel number
%2 = Block number, label
A polynomial for the angle of rotation of orientation (PO[THT]) can only be programmed, if
the active transformation supports it.
- Correction block is reorganized.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Modify the NC program
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 position programming without transformation not allowed
%1 = Channel number
%2 = Block number, label
Position information was programmed for an axis position but no transformation was
active.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify the program.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 PTP movement not allowed
%1 = Channel number
%2 = Block number, label
The PTP G code was programmed for a movement other than G0 or G1.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify the program.
Clear alarm with the RESET key. Restart part program.