10.04
4115
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4150
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4152
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Time ratio communication to Ipo changed to %1
%1 = String (new PLC cycle time)
The value of the machine data 10072 has been adapted. This can only occur, if the value
of the machine data is smaller than one and the time thus calculated is no multiple of the
position control cycle.
- Alarm display.
The machine data $MN_COM_IPO_TIME_RATIO has been adapted. Please check to
ensure that the calculated value is correct.
Clear alarm with the RESET key. Restart part program.
Channel %1 invalid M function subprogram call configured
%1 = Channel number
The machine data $MN_M_NO_FCT_CYCLE[n] or $MN_M_NO_FCT_CYCLE_PAR con-
tains invalid configuration data: An M function, which is used by the system and can not
be replaced by a subprogram call has been specified in the machine data
$MN_M_NO_FCT_CYCLE[n] for the configuration of the subprogram call via M function:
• M0 to M5,
• M17, M30,
• M19, M40 to M45,
• M function for selecting spindle/axis mode according to
$MC_SPIND_RIGID_TAPPING_M_NR (default: M70),
• M functions for nibbling/punching as configured in $MC_NIBBLE_PUNCH_CODE if acti-
vated by $MC_PUNCHNIB_ACTIVATION.
• Also M96 to M99 for applied external language ($MN_MM_EXTERN_LANGUAGE).
The machine data $MN_M_NO_FCT_CYCLE_PAR contains an invalid array index of
$MN_M_NO_FCT_CYCLE[n]. Currently, the values 0 to 9 are permissible. The affected
machine data is reset to the default value -1. This deactivates the function.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Configure an M function in the machine data $MN_M_NO_FCT_CYCLE[n] that is not
assigned by the system, or configure a permissible array index in the machine data
$MN_M_NO_FCT_CYCLE_PAR.
Switch control OFF - ON.
Illegal configuration of the 'Block display with absolute values' function
The "Block display with absolute values" function has been illegally parameterized:
• An illegal block length has been set with $MC_MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range: 0, 1,
128 to 512
• An invalid display range has been set with $MC_MM_ABSBLOCK_BUFFER_CONF[].
While ramping up, the machine data will be checked for the following upper and lower lim-
its:
• 0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
• 0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= ($MC_MM_IPO_BUFFER_SIZE +
$MC_MM_NUM_BLOCKS_IN_PREP). Alarm 4152 is issued if the limits are violated.