Siemens SINUMERIK 840D Diagnostics Manual page 498

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
103000
Definitions:
Remedy:
Program Continuation:
103001
Definitions:
Remedy:
Program Continuation:
103002
Definitions:
Remedy:
Program Continuation:
103003
Definitions:
Remedy:
Program Continuation:
103004
Definitions:
Remedy:
Program Continuation:
103006
Definitions:
Remedy:
Program Continuation:
103007
Definitions:
Remedy:
Program Continuation:
1-498
There is no correction block on the NCK
The following is valid up to SW 3.x:
The correction block window cannot be opened. No program correction is possible in the
operating mode "Machine".
The following is valid up to SW 4.1:
The correction block window can be opened in the "Stop program" state.
The program that is currently being executed is opened for editing.
The program part that has not yet been recorded by the NCK's
program processing can be changed permanently.
--
Internal
Selection is only possible after being enabled or in the RESET state.
In order to execute the desired function, the current channel has to be in the RESET
state, e.g. "Program selection".
Trigger reset.
Internal
Copying to the clipboard is not possible
The NCK rejects a copy-action to the clipboard because, for example, no more memory is
available or the maximum manageable amount of programs has been exceeded.
Delete the programs not currently required.
Internal
MDI clipboard cannot be deleted
The NCK rejects a deletion of the clipboard because the clipboard is currently being exe-
cuted.
Wait until the MDI program has been executed or trigger an NC reset.
Internal
Block search not possible
The search run cannot be started because the channel is active.
Wait until the program has been executed or trigger an NC reset.
Internal
Block search without calculation only possible on the main program level.
No subroutine calls can be processed during a block search without calculation.
If subroutines are to be processed, a search run with calculation has to be performed.
Internal
Ending overstore is not possible in this channel state.
Overstore cannot be ended because the channel is still active.
Wait until the overstore procedure has finished or trigger an NC reset.
Internal
 Siemens AG, 2004. All rights reserved