Siemens SINUMERIK 840D Diagnostics Manual page 93

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
10242
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10243
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10249
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10250
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10251
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
[up to SW 3.x only] Mode group %2 mode change in channel %1 not possible at this
time
%1 = Channel number
%2 = Mode group number
The internal state of the indicated channel is not uniquely defined (e.g. in initialization
mode or waiting for an acknowledgement from the sequence control system).
- Alarm display.
You can change the mode by pressing the Reset key and repeating the mode selection.
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Channel %1: mode group %2 cannot change mode
%1 = Channel number
%2 = Mode group number
The requested mode change cannot be executed because NC functions are still running
in the other channel, e.g. part program execution.
- Alarm display.
You can change the mode by pressing the Reset key and repeating the mode selection.
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Mode group %2 channel %1: mode change command canceled
%1 = Channel number
%2 = Mode group number
An error occurred while a mode change command was active, with the result that the
sequence could not be continued.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Press RESET and select the mode again.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
[up to SW 3.x only] Channel %1 reorganization of block processing not possible at
this time
%1 = Channel number
REORG is not possible at present.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
--
Clear alarm with the RESET key. Restart part program.
[up to SW 3.x only] Channel %1
%1 = Channel number
REORG is not possible at present.
1 Alarms