Siemens SINUMERIK 840D Diagnostics Manual page 25

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
2900
Definitions:
Reactions:
Remedy:
Program Continuation:
3000
Definitions:
Reactions:
Remedy:
Program Continuation:
3001
Definitions:
Reactions:
Remedy:
Program Continuation:
4000
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Reboot is delayed
This alarm indicates a delayed reboot.
This alarm only occurs when reboot was carried out by the MMC via PI - "_N_IBN_SS"
and MD 11410 $MN_REBOOT_DELAY_TIME was set greater than zero.
The alarm can be suppressed with $MN_SUPPRESS_ALARM_MASK BIT 20.
- NC not ready.
- The NC switches to follow-up mode.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
See $MN_REBOOT_DELAY_TIME and $MN_SUPPRESS_ALARM_MASK.
Switch control OFF - ON.
Emergency stop
The EMERGENCY STOP request is applied to the NCK/PLC interface (DB 10, DBX
56.1).
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Please inform the authorized personnel/service department. Rectify the cause of EMER-
GENCY STOP and acknowledge EMERGENCY STOP via the PLC/NCK interface (DB
10, DBX 56, Bit 2).
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Internal emergency stop
This alarm is not displayed.
- NC not ready.
- Local alarm reaction.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
No remedy required
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 machine data %2[%3] has gap in axis assignment
%1 = Channel number
%2 = String: MD identifier
The assignment of a machine axis to a channel by the machine data 20070
AXCONF_MACHAX_USED must be contiguous. At system power-up (Power On) gaps
are detected and displayed as an alarm.
1 Alarms
1-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents