10.04
61113
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61114
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61115
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61116
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 parameter _CRAD for corner radius too large
%1 = Channel number
%2 = Block number, label
The parameter for the corner radius _CRAD has been specified too large. Alarm triggered
by following cycle: POCKET3.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Parameter must be reduced.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 machining direction G41/G42 incorrectly defined
%1 = Channel number
%2 = Block number, label
The machining direction of the cutter radius compensation G41/G42 has been incorrectly
selected. Alarm triggered by following cycle: CYCLE72.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Change machining direction.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 approach or retract mode (straight line/circle/plane/space)
incorrectly defined
%1 = Channel number
%2 = Block number, label
The approach or retract mode to/from the contour has been incorrectly defined. Alarm
triggered by following cycle: CYCLE72.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Check parameter _AS1 or _AS2.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 approach or retraction path = 0
%1 = Channel number
%2 = Block number, label
The approach or retract path has been specified with zero. Alarm triggered by following
cycle: CYCLE72.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Check parameter _LP1 or _LP2.
Clear alarm with the RESET key. Restart part program