10.04
4050
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4060
Definitions:
Reactions:
Remedy:
Program Continuation:
4062
Definitions:
Reactions:
Remedy:
Program Continuation:
4065
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
NC code identifier %1 cannot be reconfigured to %2
%1 = String: Old identifier
%2 = String: New identifier
Renaming of an NC code was not possible for one of the following reasons:
• The old identifier does not exist
• The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Correct machine data 10712:
NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier
e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT",
NC_USER_CODE_CONF_NAME_TAB [11] = " " clears the ROT function from the control
Switch control OFF - ON.
Standard machine data loaded
The standard MD were loaded because
• a cold start was requested or
• the MD buffer voltage failed or
• an initialization was requested for loading the standard machine data (MD 11200
INIT_MD).
- Alarm display.
Please inform the authorized personnel/service department. After automatically loading
the standard MDs, the individual MDs must be entered or loaded in the relevant system.
Clear alarm with the RESET key. Restart part program.
Backup data loaded
The user data saved in the flash memory are loaded to the SRAM.
- Alarm display.
Please inform the authorized personnel/service department. Load specific machine data
again.
Clear alarm with the RESET key. Restart part program.
Buffered memory was restored from backup medium (potential loss of data!)
Only occurs with PC-NC. A possible data integrity error was detected in the buffered
memory during power-up. The buffered memory was initialized with the last backup copy.
Changes in the buffered memory, which have been made since the last backup copy
update, have been lost. Backup copies of the buffered memory are updated (on the hard
disk) every time the control is shut down normally.