10.04
27102
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
27103
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4
%1 = Axis number
%2 = SG level for which the difference was determined
%3 = Monitoring status safe velocity
%4 = Monitoring status safe velocity
During cross-comparison of result list 1 a difference was detected between the NCK and
drive monitoring channels in the status of safe velocity monitoring.
• Safe velocity 1: Bit 6, 7 in result list 1
• Safe velocity 2: Bit 8, 9 in result list 1
• Safe velocity 3: Bit 10, 11 in result list 1
• Safe velocity 4: Bit 12, 13 in result list 1
Monitoring status (%3, %4):
• OFF = Monitoring is inactive in this monitoring channel
• OK = Monitoring is active in this monitoring channel, limit values are not violated
• L+ = Monitoring is active in this monitoring channel, upper limit exceeded
• L- = Monitoring is active in this monitoring channel, lower limit exceeded
- Alarm display.
If a safe monitoring was active, STOP B was also triggered automatically. In this case, a
power OFF/ON of the control will be required.
Check whether the safe inputs have switched to the same status in both monitoring chan-
nels within the permissible time tolerance.
For further diagnostics, the drive machine data 1391, 1392 and the servo trace signals
"Result list 1, NCK" and "Result list 1, drive" can be used.
Clear alarm with the RESET key. Restart part program
Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4
%1 = Axis number
%2 = Number of safe limit position
%3 = Monitoring status safe limit position
%4 = Monitoring status safe limit position
During cross-comparison of result list 1 a difference was detected between the NCK and
drive monitoring channels in the status of safe limit position monitoring.
• Safe limit position 1: Bit 2, 3 in result list 1
• Safe limit position 2: Bit 4, 5 in result list 1
Monitoring status:
• OFF = Monitoring is inactive in this monitoring channel
• OK = Monitoring is active in this monitoring channel, limit values are not violated
• L+ = Monitoring is active in this monitoring channel, upper limit exceeded
• L- = Monitoring is active in this monitoring channel, lower limit exceeded
- Alarm display.
If a safe monitoring was active, STOP B was also triggered automatically. In this case, a
power OFF/ON of the control will be required.
Check whether the safe inputs have switched to the same status in both monitoring chan-
nels within the permissible time tolerance.
For further diagnostics, the drive machine data 1391, 1392 and the servo trace signals
"Result list 1, NCK" and "Result list 1, drive" can be used.
Clear alarm with the RESET key. Restart part program