Siemens SINUMERIK 840D Diagnostics Manual page 470

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
62201
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
62303
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
62304
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
62305
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-470
Channel %1 block %2 Programmable offset in positive Z direction not permitted
%1 = Channel number
%2 = Block number, label channel number
ShopTurn does not allow a work offset in positive Z direction via a coordinate transforma-
tion.
- Alarm display.
Program a work offset in positive Z direction not via a coordinate transformation (Menu
Program - Various - Transformations - Offset), but via the work offset option (G54, ...).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Safety margin exceeded
%1 = Channel number
%2 = Block number, label channel number
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check setpoint value
Increase parameter _TSA
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Allowance
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
The difference between actual and setpoint value is larger than upper tolerance limit
(parameter _TUL).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Undersize
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE971, CYCLE972, CYCLE974,
CYCLE977, CYCLE978, CYCLE979, CYCLE982, CYCLE994
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
The difference between actual and setpoint value is smaller than lower tolerance limit
(parameter _TLL).
Clear alarm with the RESET key. Restart part program
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement