1 Alarms
Program Continuation:
12560
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12570
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12571
Parameters:
Definitions:
Reactions:
1-162
• With machine data $MN_NC_LANGUAGE_CONFIGURATION = 2 or 4, only those lan-
guage commands are created, the option of which has been set or the function of which is
active.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 programmed value %3 exceeds allowed limits
%1 = Channel number
%2 = Block number, label
%3 = Source string
In a value assignment, the permissible value range of the data type has been exceeded.
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Assign value within the value range of the various data types, or if necessary use another
type in order to increase the size of the value range, e.g. INT ->REAL.
Value ranges of the various variable types:
• REAL: Property: Fractional number with dec. pt., value range: +/-(2-1022-2+1023)
• INT: Property: Integers with signs, value range: +/-(231-1)
• BOOL: Property: Truth value TRUE, FALSE, value range: 0,1
• CHAR: Property: 1 ASCII character, value range: 0-255
• STRING: Property: Character string (max. 100 values), value range: 0-255
• AXIS: Property: Axis addresses, value range: Axis names only
• FRAME: Property: Geometric information, value range: As for axis paths
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 too many motion synchronous actions in %3
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
No more than 16 actions are allowed in a block with motion synchronous action.
- Correction block
- Interface signals are set.
- Alarm display.
Reduce the number of programmed actions.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 %3 not permissible for motion synchronous action
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
The predefined subprogram %3 specified here is not allowed in a block with motion syn-
chronous action. It may only be contained in a "normal" block.
- Correction block
- Interface signals are set.
- Alarm display.
 Siemens AG, 2004. All rights reserved