10.04
111310
Definitions:
Reactions:
Remedy:
Program Continuation:
111311
Definitions:
Reactions:
Remedy:
Program Continuation:
111400
Definitions:
Reactions:
Remedy:
Program Continuation:
111410
Parameters:
Definitions:
Remedy:
Program Continuation:
111411
Definitions:
Reactions:
Remedy:
Program Continuation:
111420
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Error when selecting zero offset
In the asynchronous subroutine, internal settings in the NC were triggered by the operator
panel. If one of the alarms from 11306 to 111310 occurs, these settings cannot be carried
out.
- Alarm display.
Perform an NCK reset
Internal
NC start not possible: Deselect single block
A program was activated with block search, while at the same time single block was
active.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Deselect single block.
Internal
Unknown PLC error
The PLC has announced an error that is unknown in the operator panel.
- NC Start disable in this channel.
- Alarm display.
Inform Siemens.
Switch control OFF - ON.
Tool %1 was created
%1 = Tool number
When ManualTurn is booted, a check is run to see whether all standard tools are avail-
able. If this is not the case, the missing tools will be created automatically. If several tools
are created, they will be output in an aggregate signal.
Meaning: Example: %1 Number of the tool that was created, 5 %1 First and last tool that
were created, 5...16.
--
Internal
%1 Tool(s) can (could) not be created
When ManualTurn is booted, a check is run to see whether all standard tools are avail-
able. If this is not the case, the missing tools will be created automatically. Hereby, the
specified number of tools could not be created.
- NC Start disable in this channel.
- Alarm display.
Increase machine data 18082 $MM_NUM_TOOL by the specified amount.
Internal
Error during the inch/metric conversion! Check all data!
The switchover of the data for the inch/metric conversion was not completed. This alarm
can only appear in the event of hardware defects.
- NC Start disable in this channel.
- Alarm display.
1 Alarms