Siemens SINUMERIK 840D Diagnostics Manual page 349

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
22054
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
22055
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
22060
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
22062
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
In the case of SPOS/SPOSA with an absolute encoder, only the referencing mode
ENC_REFP_MODE = 2 is supported! SPOS/SPOSA does not support
ENC_REFP_MODE = 6 at all!
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Modify setting of ENC_REFP_MODE or change to JOG+REF and then reference.
Clear alarm with the RESET key. Restart part program
Channel %1 block %3 spindle %2 improper punching signal
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
If the punching signal is irregular between the punching strokes, this alarm is generated
according to machine data.
- Alarm display.
Indicates poor condition of the punching hydraulics.
Clear alarm with the Delete key or NC START.
Channel %1 block %3 spindle %2 configured positioning speed is too high
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
The current position is not referenced with the MS position although reference is made to
it.
- Alarm display.
Correct NC part program. Create the zero mark synchronization by positioning, by rota-
tion (at least 1 revolution) in speed control mode or G74 before switching the alarm gener-
ating function on.
Clear alarm with the Delete key or NC START.
Channel %1 position control expected for axis/spindle %2
%1 = Channel number
%2 = Axis name, spindle number
The programmed coupling type (DV, AV) or the programmed function requires position
control.
- Alarm display.
Activate position control, e.g. by programming SPCON.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is
not reached
%1 = Channel number
%2 = Axis name, spindle number
The configured zero marker search velocity is not reached.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
1 Alarms