Siemens SINUMERIK 840D Diagnostics Manual page 169

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
12650
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12660
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12661
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Correct part program. If necessary, move parts to a subroutine.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 axis identifier %3 different in channel %4
%1 = Channel number
%2 = Block number
%3 = Source symbol
%4 = Channel number with different axis definition
In cycles that are preprocessed at Power On, only those geometry and channel axis iden-
tifiers may be used that exist in all channels with the same meaning. In different channels,
different axis indices are assigned to the axis identifier.
The axis identifiers are defined via machine data 20060 AXCONF_GEOAX_NAME_TAB
and 20080 AXCONF_CHANAX_NAME_TAB. Example: C is the 4th channel axis in chan-
nel 1 and the 5th channel axis in channel 2.
If the axis identifier C is used in a cycle that is preprocessed at Power On, then this alarm
is issued.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department.
1. Modify machine data: Select the same identifiers for geometry and channel axes in all
channels. Example: The geometry axes are called X, Y, Z in all channels. They can then
also be programmed directly in preprocessed channels.
2. Do not program the axis directly in the cycle but define it as a parameter of the axis
type. Example: Cycle definition:
PROC DRILL(AXIS DRILLAXIS) G1 AX[DRILLAXIS]=10 F1000 M17
Call from the main program:
DRILL(Z)
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 motion synchronous action: variable %3 reserved for motion
synchronous actions and technology cycles
%1 = Channel number
%2 = Block number
%3 = Variable name
The displayed variable may only be used in motion synchronous actions or in technology
cycles. For example, '$R1' may only be used in motion synchronous actions. In standard
part programs R parameters are programmed with R1.
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 technology cycle %3: no further subprogram call possible
%1 = Channel number
%2 = Block number
%3 = Name of the technology cycle call
In a technology cycle it is not possible to call a subroutine or another technology cycle.
1 Alarms
1-169

Hide quick links: