Siemens SINUMERIK 840D Diagnostics Manual page 432

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
61203
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61204
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61205
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61210
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-432
Channel %1 block %2 no positioning cycle
%1 = Channel number
%2 = Block number, label
No positioning cycle was programmed in the machining block. Alarm triggered by follow-
ing cycles: CYCLE108, E_MANAGE, F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program positioning block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 unknown technology cycle
%1 = Channel number
%2 = Block number, label
The specified technology cycle in the machining block is unknown. Alarm triggered by fol-
lowing cycles: E_MANAGE, F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Delete and reprogram the technology block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 unknown positioning cycle
%1 = Channel number
%2 = Block number, label
The specified positioning cycle in the machining block is unknown. Alarm triggered by fol-
lowing cycles: E_MANAGE, F_MANAGE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Delete and reprogram the positioning block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 block search element not found
%1 = Channel number
%2 = Block number, label
The element specified for the block search does not exist. Alarm triggered by following
cycles: E_MANAGE, E_PS_CIR, E_PS_MRX, E_PS_SEQ, F_MANAGE, F_PS_CIR,
F_PS_MRX, F_PS_SEQ.
- Interpreter stop
- Channel not ready.
- Interface signals are set.
- Alarm display.
Repeat block search.
Clear alarm with the RESET key. Restart part program
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents