Siemens SINUMERIK 840D Diagnostics Manual page 269

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
16906
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16907
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16908
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16909
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16911
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16912
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 program control: action %2<ALNX> is aborted due to an alarm
%1 = Channel number
%2 = Action number/action name
The action was aborted due to an alarm.
- Alarm display.
Eliminate the error and acknowledge the alarm. Then repeat the operation.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> only possible in stop state
%1 = Channel number
%2 = Action number/action name
This action may only be performed in Stop state.
- Alarm display.
Check the program status and channel status.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> only possible in reset state or at the block end
%1 = Channel number
%2 = Action number/action name
This action may only be performed in Reset state or at end of block.
In JOG mode, no axis that is traversed as geometry axis in the switched coordinate sys-
tem, must be active as PLC or command axis (started through static synchronized action)
on mode change. This means that axes like that must be in the state 'neutral axis' again.
- Alarm display.
Check the program status and channel status.
Check in JOG mode whether the axes are PLC or command axes.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> not allowed in current mode
%1 = Channel number
%2 = Action number/action name
You have to activate a different operating mode for the function to be activated.
- Alarm display.
Check operation and operating state.
Clear alarm with the Delete key or NC START.
Channel %1 mode change is not allowed
%1 = Channel number
The change from overstoring into another operating mode is not allowed.
- Alarm display.
After overstoring is terminated, it is possible to change to another operating state again.
Clear alarm with the Delete key or NC START.
Channel %1 program control: action %2<ALNX> only possible in reset state
%1 = Channel number
%2 = Action number/action name
1 Alarms
1-269

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents