10.04
Reactions:
Remedy:
Program Continuation:
26105
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
26106
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Axes of this channel must be re-referenced.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Check the cycle settings.
• Increase the cycle time if necessary.
• Power-up the drive again.
• Check drive software.
Clear alarm with the RESET key. Restart part program
Drive of axis %1 not found
%1 = Axis name, spindle number
The drive configured for the specified axis could not be found. For example, a Profibus
slave was configured on the NC but is not contained in SDB1000.
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Possible causes:
• $MA_CTRLOUT_TYPE not equal to 0 as a result of an oversight; the drive should actu-
ally be simulated (= 0).
• $MA_CTRLOUT_MODULE_NR entered incorrectly, i.e. the logical drive numbers were
exchanged and an invalid value is stored for this drive in
$MN_DRIVE_LOGIC_ADDRESS (see 3.) or a drive number which does not exist on the
bus was entered (check the number for slaves, for example).
• $MN_DRIVE_LOGIC_ADDRESS contains values which were not configured on the
Profibus (i.e. the values are not in SDB1000) or different addresses were selected for the
input and output slots of the drive in the Profibus configuration.
Switch control OFF - ON.
Encoder %2 of axis %1 not found
%1 = Axis name, spindle number
%2 = Encoder number
The drive configured for the specified axis could not be found. For example, a Profibus
slave was configured on the NC but is not contained in SDB1000.
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
1 Alarms