1 Alarms
Reactions:
Remedy:
Program Continuation:
310703
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
310704
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
310705
Parameters:
Definitions:
1-628
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Change the position controller pulse rate on the NC.
Switch control OFF - ON.
Axis %1 drive %2 monitoring cycle time invalid
%1 = NC axis number
%2 = Drive number
Monitoring cycle MD 5002: MONITOR_CYCLE_TIME (monitoring cycle) is invalid.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please refer to the drive functions "FB/DB1" MD 1002.
Switch control OFF - ON.
Axis %1 drive %2 speed controller cycle times of axes differ
%1 = NC axis number
%2 = Drive number
The speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME must be identical for
both axes on 2-axis modules.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Set an identical speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME for both
axes.
Switch control OFF - ON.
Axis %1 drive %2 monitoring cycle times of axes differ
%1 = NC axis number
%2 = Drive number
The monitoring cycle MD 5002: MONITOR_CYCLE_TIME must be identical for both axes
on 2-axis modules.