Channel %1 block %2 combine OSCILL and POSP during oscillation with infeedmo-
tion
%1 = Channel number
%2 = Block number, label
When oscillating controlled by synchronized actions, the assignment of oscillating and
infeed axis (OSCILL) as well as the definition of the infeed (POSP) must be carried out in
one NC block.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: no end point programmed
%1 = Channel number
%2 = Block number, label
No end point was programmed for the involute. This is either possible via direct program-
ming with the geometry axis identifiers or by specifying the angle between start and end
vector.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: angle of rotation too large
%1 = Channel number
%2 = Block number, label
With programming of the angle of rotation (with AR) for involute interpolation, the maxi-
mum programmable angle of rotation is limited if the involute is moving towards the basic
circle. The maximum value is reached if the involute touches the basic circle. With
MD_INVOLUTE AUTO_ANGLE_RESTRICTION = TRUE, each angle is accepted without
an alarm; if necessary, the angle is automatically limited during interpolation.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 involute: start point invalid
%1 = Channel number
%2 = Block number, label
With involute interpolation, the start point of the involute must be outside the basic circle.
The programmed center point or radius must be adapted accordingly.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition