1 Alarms
61357
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61358
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61359
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61360
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-452
Channel %1 block %2 No resources free
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE106.
Not enough NC memory space available.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Delete the files.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Error on recording
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE106.
Internal error
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Call the hotline!
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Continue with RESET
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE106.
Internal error
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Call the hotline!
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Log job undefined - continue with RESET
%1 = Channel number
%2 = Block number, label channel number
Cycle CYCLE106 was called by a wrong parameter.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
--
Clear alarm with the RESET key. Restart part program