Siemens SINUMERIK 840D Diagnostics Manual page 540

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
300011
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300012
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-540
Please inform the authorized personnel/service department. Check the configuration
data, the assignment of setpoints and actual values for the drive motor and the position
encoder.
MDs for the drive configuration:
• Modify MD 13000: DRIVE_IS_ACTIVE
• Modify MD 13010: DRIVE_LOGIC_NR
• Modify MD 13020: DRIVE_INVERTER_CODE
• Modify MD 13030: DRIVE_MODULE_TYPE
• Modify MD 13040: DRIVE_TYPE
• MDs for the setpoint/actual-value assignment:
• Modify MD 30110: CTRLOUT_MODULE_NR
• Modify MD 30130: CTRLOUT_TYPE
• Modify MD 30220: ENC_MODULE_NR
• Modify MD 30230: ENC_INPUT_NR
• Modify MD 30240: ENC_TYPE
It might be necessary to first declare an NC axis in the channel for this drive (MD 20070
AXCONF_MACHAX_USED = K, [K ...channel axis no.]).
Switch control OFF - ON.
Axis %1 drive %2 hardware version of spindle not supported
%1 = NC axis number
%2 = Drive number
An old spindle power section (so-called 186-HSA) is connected to the drive bus. This
spindle drive is not supported by SINUMERIK 840D. Ramp-up is interrupted.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. A DSP spindle module must
be ordered and fitted.
Switch control OFF - ON.
Axis %1 drive %2 hardware version of control module not supported
%1 = NC axis number
%2 = Drive number
There is a drive module with an "old" control module on the drive bus. 810D does not sup-
port these modules. Ramp-up is interrupted.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Order standard or perfor-
mance control module and exchange with "old".
Switch control OFF - ON.