10.04
Remedy:
Program Continuation:
2190
Definitions:
Reactions:
Remedy:
Program Continuation:
2192
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
2193
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
2194
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Reset initialization switch to zero.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Hardware plug-in module for communication with the digitizer missing
MD $MN_ASSIGN_DIGITIZE_TO_CHAN was used to activate the digitizing function by
assigning it to a channel. The function requires a hardware module (RS422 board
plugged into the NCU) for communication with the digitizing unit. This module was not
found when booting.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Plug in communications
module or cancel channel assignment.
Switch control OFF - ON.
No NCU link module exists, MD %1 reset
%1 = String: MD identifier
An attempt was made to activate the NCU link functionality but the hardware is not avail-
able. The MD was reset. Only occurs with the NCU link system
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Install the hardware module and activate the function again (MD).
Switch control OFF - ON.
'Safety Integrated' is not available for link axis %1.
%1 = Machine axis index
The "Safety Integrated" function is not available for a link axis. Only occurs with the NCU
link system
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Use "Safety Integrated" function for local axes only.
Switch control OFF - ON.
Link axis active and $MN_SERVO_FIFO_SIZE != 3
At least one axis is to be distributed via NCU link, then the machine data