10.04
Remedy:
Program Continuation:
300860
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300861
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300862
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300863
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Please inform the authorized personnel/service department.
• Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) or
• Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for
DC link monitoring).
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed
%1 = NC axis number
%2 = Drive number
The value entered for the emergency retraction speed in MD1639:
$MD_RETRACT_SPEED (emergency retraction speed) is greater than MD1146:
$MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department.
• Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or
• Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed
%1 = NC axis number
%2 = Drive number
The value in MD1635: $MD_GEN_AXIS_MIN_SPEED $MD_GEN_AXIS_MIN_SPEED
(minimum generator axis speed) is greater than the value in MD1146:
$MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department.
• Modify MD 1635: $MD_GEN_AXIS_MIN_SPEED generator axis) or
• Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 emergency retraction mode/generator mode already active
%1 = NC axis number
%2 = Drive number
Emergency retraction or generator mode already active.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Check parameterization/
machine data.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Axis %1 drive %2 emergency retraction mode/generator mode invalid
%1 = NC axis number
%2 = Drive number
Value specified by the NC via a G command must be in the range 0 to 7.
- Interface signals are set.
- Alarm display.