SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
NCU link connection to all other NCUs of the link network has been aborted
All NCUs in the NCU link network exchange data cyclically (sign-of-life). If this alarm
occurs, sign-of-life signals have not been received from any other NCUs on the NCU net-
work. This fault in the link can have various causes:
• Defective hardware.
• The machine data which configure the NCU link are not the same on all NCUs.
• An identical interpolator cycle time has not been selected on all NCUs.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check the IPO cycle on all the NCUs.
If necessary, check NCU link-specific alarms first.
Switch control OFF - ON.
NCU link connection to the NCU %1 of the link network has been aborted
%1 = NCU number
All NCUs in the NCU link network exchange data cyclically (sign-of-life). If this alarm
occurs, sign-of-life signals have not been received from one other NCU on the NCU net-
work (see alarm parameters). This fault in the link can have various causes:
• Defective hardware.
• The machine data which configure the NCU link are not identical on all NCUs.
• An identical interpolator cycle time has not been selected on all NCUs.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Check the IPO cycle on all the NCUs.
• If necessary, check NCU link-specific alarms first.
Switch control OFF - ON.
Error on activation of machine data, NCU network-wide machine data were modi-
fied by NCU %1
%1 = NCU number
During the activation of machine data with NEWCONFIG or during an operator panel
RESET, NCU network-wide machine data were modified on another NCU. This alarm can
only occur when a link connection is active.
- NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Repeat the operator action or, if NEWCONFIG is activated by an NC program, terminate
the program with Reset.
Clear alarm with the RESET key. Restart part program
1 Alarms