Siemens SINUMERIK 840D Diagnostics Manual page 17

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
1014
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1015
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1016
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Clear alarm with the RESET key. Restart part program.
Channel %1 system error %2
%1 = Channel number
%2 = System error number
With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
- Mode group not ready.
- Local alarm reaction.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 axis %2 system error %3
%1 = Channel number
%2 = Axis number
%3 = System error number
With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error. Especially
with parameter %3 (system error number) = 840001 = Problem with tool management,
the identification for the axis is not contained in parameter %2, but instead, further infor-
mation for the diagnostics (= Status of the data management/magazine no./location no./T
no.)
- Local alarm reaction.
- Channel not ready.
- Interface signals are set.
- Alarm display.
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Clear alarm with the RESET key. Restart part program.
Channel %1 axis %2 system error %3
%1 = Channel number
%2 = Axis number
%3 = System error number
With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
- Mode group not ready.
- Local alarm reaction.
- Channel not ready.
- Interface signals are set.
- Alarm display.
1 Alarms
1-17

Hide quick links:

Advertisement

Table of Contents
loading