Siemens SINUMERIK 840D Diagnostics Manual page 30

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
4012
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4013
Parameters:
Definitions:
Reactions:
1-30
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD
• Geometry axes: 20060 AXCONF_GEOAX_NAME_TAB
• Channel axes: 10000 AXCONF_MACHAX_NAME_TAB
Switch control OFF - ON.
Invalid identifier used in machine data %1[%2]
%1 = String: MD identifier
%2 = Index: MD array
The selected identifier is invalid. Valid identifiers are:
• AX1 - AXn: Machine axis identifiers
• N1AX1 - NnAXm: Link axis identifiers (NCU + machine axis), only occurs with 'NCU link'
expansion level!
• C1S1 - CnSm: Container axis identifiers (container + container location). Only occurs
with 'axis container' expansion level!
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Use the correct identifier.
Switch control OFF - ON.
Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3
%1 = String: MD identifier
%2 = Index: MD array
%3 = MD value of master NCU
The link module configuration detected on the local NCU is different from the master NCU
of the NCU cluster. The link module configuration defines the system clock time, the com-
munication baudrate and the maximum number of message transfer retries.
The following machine data are used for this purpose:
• SYSCLOCK_SAMPL_TIME_RATIO,
• IPO_SYSCLOCK_TIME_RATIO,
• LINK_RETRY_CTR,
• LINK_BAUDRATE_SWITCH,
• SYSCLOCK_CYCLE_TIME
The values of these machine data must be the same on all NCUs.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
 Siemens AG, 2004. All rights reserved