1 Alarms
70001
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70002
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70003
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70004
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-474
Channel %1 Yf is larger than distance C1-Cy
%1 = Channel number
In JOG mode, the Yf axis is traversed. The value of the Yf axis is larger than the distance
C1-Cy
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Traverse Yf axis in JOG in opposite traversing direction
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 block %2 Yf has been programmed larger than distance C1-Cy
%1 = Channel number
%2 = Block number
In the part program, one position in the Yf axis has been programmed larger than the dis-
tance C1-Cy
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 YF is larger than the effective arm length
%1 = Channel number
In JOG mode, the Yf axis is traversed. The value of the Yf axis is larger than the sum of
the arm lengths and the current tool length in the Z direction.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Traverse Yf axis in JOG mode in opposite traversing direction
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 block %2 Yf has been programmed larger than the effective arm length
%1 = Channel number
In the part program, one position in the Yf axis has been programmed larger than the
effective arm lengths
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program