Appendix
A.1
New and extended functions
A.1.1
Firmware version 4.7 SP13
Table A-1
New functions and function changes in firmware 4.7 SP13
Function
1
SIMOTICS 1FP1 and 1FP3 synchronous-reluctance motors have also been
approved for operation with SINAMICS G120C.
2
The extended safety functions SS1, SLS, SSM and SDI are approved when
using synchronous-reluctance motors from Siemens and third-party manu‐
facturers.
3
The converter transmits the state of the fail-safe digital input F-DI 0 via
PROFIsafe when using the basic functions.
You can find more information in the "Safety Integrated" Function Manual.
"Safety Integrated" function manual
support.industry.siemens.com/cs/ww/en/view/109751320)
4
Modbus RTU:
The converter supports the combination "1 stop bit" and "no parity".
5
EtherNet/IP:
When selecting the ODVA AC/DC drive profile, although telegram 1 is pre‐
defined, it can be extended to include additional process data.
The EDS file has been extended accordingly by a telegram with a length of 6
words.
More information is provided in the "Fieldbuses" Function Manual.
"Fieldbus" function manual
support.industry.siemens.com/cs/ww/en/view/109751350)
EDS (https://support.industry.siemens.com/cs/ww/de/view/78026217)
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
(https://
(https://
SINAMICS
G120
-
✓
✓
✓
✓
✓
-
-
-
-
-
✓
✓
✓
✓
-
-
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
-
✓
A
G120D
-
✓
-
-
✓
-
✓
✓
✓
✓
-
-
✓
✓
✓
397