WAE-PORT (Wideband Access Endpoint Port)
Error Log Entries and Test to Clear Values
Table 8-716. Wideband Access Endpoint Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18 (a)
0
busyout
access-endpoint
130 (b)
None
1281 (c)
Conference Circuit
test (#7)
1537 (d)
NPE Crosstalk test
(#6)
1793 (e)
None
3840 (f)
Any
Port Audit and
Update test (#36)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. The wideband access endpoint has been busied out by a busyout
access-endpoint extension command. No calls can be made to this
extension.
b. The circuit pack has been removed or has been insane for more than
11 minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk test (#6) failed on this port. See Test #6 for repair
procedures.
e. The TN464C UDS1 Interface circuit pack has failed. See
(UDS1 Interface Circuit Pack)'' on page
f. The Port Audit and Update test (#36) failed due to an internal system error.
Enter status access-endpoint extension and verify the status of the port.
If the wideband access endpoint port is out of service, enter release
access-endpoint extension to put it back into service. Retry the test
command.
555-233-143
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test access-endpoint extension
sh r 1
WARNING OFF
release access-endpoint
extension
WARNING ON
test access-endpoint extension
MINOR
ON
test access-endpoint extension
l r 4
MINOR
ON
test access-endpoint extension
l r 3
test board UUCSS long
8-1707.
''UDS1-BD
Issue 1 May 2002
8-1867