Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-721. Common Port Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
Circuit pack removed or
SAKI Sanity test (#53)
18 (b)
0
busyout board UUCSS
23(c)
0
None
36 (d)
4368
none
125 (e)
None
217 (f)
0
None
257
65535
Control Channel test
(#52)
267 (f)
0
None
513 (h)
Any
None
769 (i)
4358
None
1025 (j)
4363
NPE Audit test (#50)
1281 (k)
Ringing Application test
(#51)
1538 (l)
Any
None
1793 (m)
Neon test (#220)
3840 (n)
Any
None
3999 (o)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has been
physically removed from the system. This error type does not apply to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or failure
of the SAKI Sanity test (#53).
Check for the physical presence of the circuit pack in the slot indicated by
the alarm. If the circuit pack is absent, insert one of the proper type. If the
circuit pack is present and its red LED is lit, see
Log Entry or with Error Type 1'' on page
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board UUCSS.
8-1876
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test board UUCSS sh r 1
MINOR
ON
WARNING OFF
release board UUCSS
WARNING OFF
MINOR
ON
WARNING ON
MINOR
ON
test board UUCSS sh r
20
WARNING ON
MINOR
ON
test board UUCSS sh
test board UUCSS l r 20
MINOR
ON
test board UUCSS r 2
WARNING
ON
MINOR
MINOR
ON
test board UUCSS r 2
''LED Alarms without Alarm
6-5.