Ordering Information; List Of Models; Power Supply Unit - Omron CP2E Manual

Micro plc designed to support data collection and machine to machine communication
Table of Contents

Advertisement

Ordering Information

■ List of Models

CPU Units and Expansion I/O Units
Unit
Name
No. of
I/O
points
CPU
Standard
10
Units
LCD type
20
LED type
10
without
display
(See note 1.)
20
Economy
10
type
(Expansion
I/O Units
20
cannot be
connected)
Communica-
9
tions type
ZEN Kit
Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual.
Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual.
Expansion I/O Units
8
Note: 1. Programming is not possible using only the CPU in the LED-type CPU Unit. ZEN Support Software or a Memory Cassette is required.
2. Cannot be connected to pre-V1 and V1 CPU Units.
3. The ZEN-8E1AR cannot be connected to a CPU Unit with DC power supply.
4. Product no longer available to order.

Power Supply Unit

Power ratings
30 W
100 to 240 VAC
Note: Product no longer available to order.
Refer to the ZEN-PA03024 Datasheet (Cat. No. L103) for detailed specifications.
LCD
Power supply
display
voltage
Yes
100 to 240 VAC
6
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
100 to 240 VAC
12
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
No
100 to 240 VAC
6
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
100 to 240 VAC
12
100 to 240V AC
12 to 24 VDC
12 to 24 VDC
Yes
100 to 240 VAC
6
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
100 to 240 VAC
12
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
100 to 240 VAC
6
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
---
100 to 240 VAC
4
100 to 240 VAC
12 to 24 VDC
12 to 24 VDC
---
Input voltage
24 VDC
Inputs
Outputs
4
Relays
Transistors
8
Relays
Transistors
4
Relays
Transistors
8
Relays
Transistors
4
Relays
8
Relays
3
Relays
4
Relays
Transistors
Output voltage
Output current
1.3 A
ZEN V2 Units
Buttons,
Analog
Model
calendar,
input
and clock
Yes
No
ZEN-10C1AR-A-V2
Yes
ZEN-10C1DR-D-V2
ZEN-10C1DT-D-V2
No
ZEN-20C1AR-A-V2
Yes
ZEN-20C1DR-D-V2
ZEN-20C1DT-D-V2
No
No
ZEN-10C2AR-A-V2
Yes
ZEN-10C2DR-D-V2
ZEN-10C2DT-D-V2
No
ZEN-20C2AR-A-V2
Yes
ZEN-20C2DR-D-V2
ZEN-20C2DT-D-V2
Yes
No
ZEN-10C3AR-A-V2
Yes
ZEN-10C3DR-D-V2
No
ZEN-20C3AR-A-V2
Yes
ZEN-20C3DR-D-V2
No
ZEN-10C4AR-A-V2
Yes
ZEN-10C4DR-D-V2
ZEN-KIT01-EV4
(See note 4.)
ZEN-KIT02-EV4
(See note 4.)
---
ZEN-8E1AR
(See notes 2, 3.)
ZEN-8E1DR
(See note 2.)
ZEN-8E1DT
(See note 2.)
Model
ZEN-PA03024
5

Advertisement

Table of Contents
loading

Table of Contents