Analog Devices ADSP-2106x SHARC User Manual page 618

Table of Contents

Advertisement

E Control/Status Registers
Register
Initialization Register
Address
Name
After RESET Group Description
0x0000
SYSCON
0x0000 0010 SC
0x0001
VIRPT
0x0002 0014 SC
0x0002
WAIT
0x21AD 6B5A SC
0x0003
SYSTAT 0x0000 0nn0 * SC
0x0004
EPB0
0x0005
EPB1
0x0006
EPB2
0x0007
EPB3
0x0008
MSGR0
0x0009
MSGR1
0x000A
MSGR2
0x000B
MSGR3
0x000C
MSGR4
0x000D
MSGR5
0x000E
MSGR6
0x000F
MSGR7
0x0010–0x0017 reserved
0x0018
BMAX
0x0000 0000 SC
0x0019
BCNT
0x0000 0000 SC
0x001A
reserved
0x001B
ELAST
0x001C
DMAC6
0x001D
DMAC7
0x0000 0000 DB
0x001E
DMAC8
0x0000 0000 DB
0x001F
DMAC9
0x0000 0000 DB
0x0020–0x002F reserved
0x0030
II4
0x0031
IM4
0x0032
C4
0x0033
CP4
0x0034
GP4
0x0035
DB4
0x0036
DA4
0x0037
DMASTAT
0x0038
II5
0x0039
IM5
0x003A
C5
0x003B
CP5
0x003C
GP5
0x003D
DB5
0x003E
DA5
0x003F
reserved
0x0040
II6
0x0041
IM6
0x0042
C6
0x0043
CP6
0x0044
GP6
0x0045
EI6
0x0046
EM6
0x0047
EC6
E – 10
www.BDTIC.com/ADI
System Configuration
Multiprocessor Vector Interrupt
External Memory Wait State Configuration
System Status
ni DB
External Port DMA FIFO Buffer 0
ni DB
External Port DMA FIFO Buffer 1
ni DB
External Port DMA FIFO Buffer 2
ni DB
External Port DMA FIFO Buffer 3
ni SC
Message Register 0
ni SC
Message Register 1
ni SC
Message Register 2
ni SC
Message Register 3
ni SC
Message Register 4
ni SC
Message Register 5
ni SC
Message Register 6
ni SC
Message Register 7
Bus Timeout Maximum
Bus Timeout Counter
ni SC
Address of Last External Access in Bank 0
† DB
DMA Channel 6 Control Reg. (Ext. Port Buffer 0 or Link Buffer 4)
DMA Channel 7 Control Reg. (Ext. Port Buffer 1 or Link Buffer 5)
DMA Channel 8 Control Reg. (Ext. Port Buffer 2)
DMA Channel 9 Control Reg. (Ext. Port Buffer 3)
ni DA
DMA Channel 4 Index (Link Buffer 2)
ni DA
DMA Channel 4 Modifier (Link Buffer 2)
ni DA
DMA Channel 4 Count (Link Buffer 2)
ni DA
DMA Channel 4 Chain Pointer (Link Buffer 2)
ni DA
DMA Channel 4 General-Purpose/2-D DMA (Link Buffer 2)
ni DA
DMA Channel 4 General-Purpose/2-D DMA (Link Buffer 2)
ni DA
DMA Channel 4 General-Purpose/2-D DMA (Link Buffer 2)
ni SC
DMA Channel Status Register
ni DA
DMA Channel 5 Index (Link Buffer 3)
ni DA
DMA Channel 5 Modifier (Link Buffer 3)
ni DA
DMA Channel 5 Count (Link Buffer 3)
ni DA
DMA Channel 5 Chain Pointer (Link Buffer 3)
ni DA
DMA Channel 5 General-Purpose/2-D DMA (Link Buffer 3)
ni DA
DMA Channel 5 General-Purpose/2-D DMA (Link Buffer 3)
ni DA
DMA Channel 5 General-Purpose/2-D DMA (Link Buffer 3)
† DA
DMA Channel 6 Index (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Modifier (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Count (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Chain Pointer (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Gen-Pur. Reg. (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Ext. Index (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Ext. Modifier (Ext. Port Buffer 0 or Link Buffer 4)
† DA
DMA Channel 6 Ext. Count (Ext. Port Buffer 0 or Link Buffer 4)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADSP-2106x SHARC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents