Chapter 4:
Receiver
The state machine works by keeping track of valid and invalid synchronization headers. Upon reset,
block lock is deasserted, and the state is LOCK_INIT. The next state is RESET_CNT where all
counters are zeroed out. The synchronization header is analyzed in the TEST_SH state. If the header
is valid, sh_cnt is incremented in the VALID_SH state, otherwise sh_count and sh_invalid_count
are incremented in the INVALID_SH state.
For the block synchronization state machine shown in
sh_invalid_cnt_max are both constants that are set to 64 and 16, respectively. From the VALID_SH
state, if sh_cnt is less than the value sh_cnt_max and test_sh is High, the next state is TEST_SH. If
sh_cnt is equal to sh_cnt_max and sh_invalid_cnt equals 0, the next state is GOOD_64 and from
there block_lock is asserted. Then the process repeats again and the counters are cleared to zeros. To
achieve block lock, the state machine must receive sh_cnt_max number of valid synchronization
headers in a row without getting an invalid synchronization header. However, when block lock is
achieved sh_invalid_cnt_max – 1, the number of invalid synchronization headers can be received
within sh_cnt_max number of valid synchronization headers. Thus, once locked, it is harder to break
lock.
Figure 4-58
RXGEARBOXSLIP numerous times because of invalid synchronization headers before achieving
data alignment. After the RXGEARBOXSLIP is issued, the state machine waits
32 RXUSRCLK2 cycles before checking for valid synchronization headers.
X-Ref Target - Figure 4-58
block_sync_i
unscrambled_data_i
begin_r
track_data_r
start_of_packet_detected_r
RXDATA
RXDATAVALID
RXGEARBOXSLIP
RXHEADER
RXHEADERVALID
RXSTARTOFSEQ
212
Send Feedback
shows a waveform of the block synchronization state machine asserting
0000000000000000
0000000000000000
Closely spaced slip pulses. State machine
asserts slip as soon as it sees bad header.
0
Figure 4-58: RX Gearbox with Block Synchronization
www.xilinx.com
Figure
4-57, sh_cnt_max and
Data check on
Data alignment
unscrambled data
Slip data
alignment
7 Series FPGAs GTP Transceivers User Guide
UG482 (v1.9) December 19, 2016
achieved