Chapter 4:
Receiver
Table 4-7: RX OOB Signaling Attributes
RXOOB_CFG
RXOOB_CLK_CFG
SATA_BURST_VAL
SATA_EIDLE_VAL
SAS_MIN_COM
SATA_MIN_INIT
SATA_MIN_WAKE
SATA_MAX_BURST
SAS_MAX_COM
SATA_MAX_INIT
SATA_MAX_WAKE
PCS_RSVD_ATTR[8]
Use Mode
To use OOB, the following RX termination conditions need to be applied:
132
Send Feedback
Attribute
Type
7-bit Binary
String
3-bit Binary
3-bit Binary
Integer
Integer
Integer
Integer
Integer
Integer
Integer
1-bit Binary
AC-coupled case: Termination voltage should be 800 mV or greater
DC-coupled case: Termination voltage should be 900 mV or greater
www.xilinx.com
Description
OOB block configuration.
Selects which clock to use for OOB.
Number of bursts to declare a COM match for
SAS/SATA.
Number of idles to declare a COM match for
SAS/SATA.
1-63. Lower bound on activity burst for COM FSM for
SAS/SATA.
1-63. Lower bound on idle count during COMSAS for
SAS.
1-63. Lower bound on idle count during
COMINIT/COMRESET for SAS/SATA.
1-63. Upper bound on activity burst for COM FSM for
SAS/SATA.
1-127. Upper bound on idle count during COMSAS
for SAS.
1-63. Upper bound on idle count during
COMINIT/COMRESET for SAS/SATA.
1-63. Upper bound on idle count during COMWAKE
for SAS/SATA.
OOB power up. The OOB circuit can be optionally
powered down when not being used.
1'b0 = Circuit powered down.
1'b1 = Circuit powered up (PCIe, SATA/SAS,
protocols/applications using OOB).