Rmon Collection History - Dell S6000 Reference Manual

Command line for the system
Hide thumbs Also See for S6000:
Table of Contents

Advertisement

Version 7.6.1.0
Version 7.5.1.0
Version 6.1.1.0

rmon collection history

Enable the RMON MIB history group of statistics collection on an interface.
S6000
Syntax
rmon collection history {controlEntry integer} [owner name]
[buckets number] [interval seconds]
To remove a specified RMON history group of statistics collection, use the no
rmon collection history {controlEntry integer} command.
Parameters
controlEntry
integer
owner name
buckets
number
interval
seconds
Defaults
none
Command
CONFIGURATION INTERFACE (config-if)
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Version
8.3.19.0
Remote Monitoring (RMON)
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
Enter the keyword controlEntry to specify the RMON
group of statistics using a value. Then enter an integer value
from 1 to 65535 that identifies the RMON group of statistics.
The integer value must be a unique index in the RMON
history table.
(OPTIONAL) Enter the keyword owner then the owner name
to record the owner of the RMON group of statistics.
(OPTIONAL) Enter the keyword buckets then the number of
buckets for the RMON collection history group of statistics.
The bucket range is from 1 to 1000. The default is 50.
(OPTIONAL) Enter the keyword interval then the number
of seconds in each polling cycle. The range is from 5 to 3600
seconds. The default is 1800 seconds.
Introduced on the S6000.
Introduced on the S4820T.