– controlEntry: specifies the RMON group of statistics using a value.
– integer: a value from 1 to 65,535 that identifies the RMON Statistics Table. The value must be
unique in the RMON Statistic Table.
– owner: (Optional) specifies the name of the owner of the RMON group of statistics.
– ownername: (Optional) records the name of the owner of the RMON group of statistics. The
default is a null-terminated string.
Example of the rmon collection statistics Command
To remove a specified RMON statistics collection, use the no form of this command.
The following command example enables the RMON statistics collection on the interface, with an ID
value of 20 and an owner of john.
Dell(conf-if-mgmt)#rmon collection statistics controlEntry 20 owner john

Configuring the RMON Collection History

To enable the RMON MIB history group of statistics collection on an interface, use the rmon
collection history command in INTERFACE CONFIGURATION mode.
Configure the RMON MIB history group of statistics collection.
CONFIGURATION INTERFACE (config-if) mode
[no] rmon collection history {controlEntry integer} [owner ownername]
[buckets bucket-number] [interval seconds]
– controlEntry: specifies the RMON group of statistics using a value.
– integer: a value from 1 to 65,535 that identifies the RMON group of statistics. The value must be
a unique index in the RMON History Table.
– owner: (Optional) specifies the name of the owner of the RMON group of statistics. The default is
a null-terminated string.
– ownername: (Optional) records the name of the owner of the RMON group of statistics.
– buckets: (Optional) specifies the maximum number of buckets desired for the RMON collection
history group of statistics.
– bucket-number: (Optional) a value associated with the number of buckets specified for the
RMON collection history group of statistics. The value is limited to from 1 to 1000. The default is
50 (as defined in RFC-2819).
– interval: (Optional) specifies the number of seconds in each polling cycle.
– seconds: (Optional) the number of seconds in each polling cycle. The value is ranged from 5 to
3,600 (Seconds). The default is 1,800 (as defined in RFC-2819).
Example of the rmon collection history Command
To remove a specified RMON history group of statistics collection, use the no form of this command.
The following command example enables an RMON MIB collection history group of statistics with an ID
number of 20 and an owner of john, both the sampling interval and the number of buckets use their
respective defaults.
Dell(conf-if-mgmt)#rmon collection history controlEntry 20 owner john
686
Remote Monitoring (RMON)