rmon hc-alarm

Set an alarm on any MIB object.
S6000
Syntax
rmon hc-alarm number variable interval {delta | absolute}
rising-threshold value event-number falling-threshold value
event-number [owner string]
To disable the alarm, use the no rmon hc-alarm number command.
Parameters
number
variable
interval
delta
absolute
rising-
threshold value
event-number
falling-
threshold value
event-number
1194
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
Enter the alarm integer number from 1 to 65535. The value
must be unique in the RMON alarm table.
The MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object
type must be a 64-bit integer.
Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is from 5 to 3600 seconds.
Enter the keyword delta to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
Enter the keyword absolute to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
Enter the keywords rising-threshold then the value (64
bit) the rising-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the rising
threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If
there is no corresponding rising-threshold event, the value is
zero.
Enter the keywords falling-threshold then the value (64
bit) the falling-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the falling
threshold exceeds its limit. This value is the same as the
alarmFallingEventIndex or the alarmTable of the RMON MIB.
Remote Monitoring (RMON)