Interpolation Filter - Analog Devices adsp-2100 Manual

Adsp-2100 family programmable single-chip microprocessors
Table of Contents

Advertisement

The high pass filter is a 4th-order elliptic filter with a passband cutoff
at 150 Hz. Stopband attenuation is 25 dB. This filter has the following
specifications:
Filter type:
Sample frequency: 8.0 kHz
Passband cutoff:
Passband ripple:
Stopband cutoff:
Stopband ripple:
(Note that these specifications apply only to this filter, and not to the
entire DAC. The specifications can be used to perform further analysis
of the exact characteristics of the filter, for example using a digital filter
design software package.)
Figure 8.3 shows the frequency response of the high pass filter.

8.3.1.2 Interpolation Filter

The DAC's anti-imaging interpolation filter contains two stages. The
first stage is is an IIR low pass filter that interpolates the data rate from
8 kHz to 40 kHz and removes images produced by the interpolation
process. The output of this stage is then interpolated to 1.0 MHz and
fed to the second stage, a sinc
produced by the 40 kHz to 1.0 MHz interpolation process.
The IIR low pass filter is a 10th-order elliptic filter with a passband
edge at 3.70 kHz and a stopband attenuation of 65 dB at 4 kHz. This
filter has the following specifications:
Filter type:
Sample frequency: 40.0 kHz
Passband cutoff*:
Passband ripple:
Stopband cutoff:
Stopband ripple:
* The passband cutoff frequency is defined to be the last point in the
passband that meets the passband ripple specification. (Note that these
specifications apply only to this filter, and not to the entire DAC. The
specifications can be used to perform further analysis of the exact
characteristics of the filter, for example using a digital filter design
software package.)
Analog Interface
4th-order high pass elliptic IIR
150.0 Hz
±0.2 dB
100.0 Hz
–25.00 dB
4
digital filter that attenuates images
10th-order low pass elliptic IIR
3.70 kHz
±0.2 dB
4.0 kHz
–65.00 dB
8
8 – 7

Hide quick links: