Programming Guide | VLT® AutomationDrive FC 301/FC 302
Setting this parameter sets the following parameters to their default settings:
Parameter 1-15 Low Speed Filter Time Const.
l
Parameter 1-16 High Speed Filter Time Const.
l
Parameter 1-17 Voltage Filter Time Const.
l
Parameter 1-30 Stator Resistance (Rs)
l
Parameter 1-31 Rotor Resistance (Rr)
l
Parameter 1-33 Stator Leakage Reactance (X1)
l
Parameter 1-34 Rotor Leakage Reactance (X2)
l
Parameter 1-35 Main Reactance (Xh)
l
Parameter 1-36 Iron Loss Resistance (Rfe)
l
Parameter 4-18 Current Limit
l
Parameter 14-31 Current Lim Ctrl, Integration Time
l
Parameter 14-43 Motor Cosphi
l
Parameter 45-33 Alarm High
l
Parameter 45-62 Load Threshold
l
Enter the nominal motor current value from the motor nameplate data. The data is used for calculating torque, motor overload
protection, and so on.
1-25 Motor Nominal Speed
Default value:
Size related
Setup:
All setups
Data type:
Uint16
This parameter cannot be adjusted while the motor is running.
Changing this parameter will affect settings of other parameters.
Enter the nominal motor speed value from the motor nameplate data. The data is used for calculating motor compensations.
1-26 Motor Cont. Rated Torque
Default value:
Size related
Setup:
All setups
Data type:
Uint32
Changing this parameter sets certain other parameters to their default settings.
© 2024.09
NOTICE
Parameter type:
Conversion index:
Change during operation:
NOTICE
NOTICE
Parameter type:
Conversion index:
Change during operation:
NOTICE
Parameter Descriptions
Range, 10 - 60000 RPM
67
False
Range, 0.1 - 10000.0 Nm
-1
False
AU275636650261en-003201 / 130R0334 |
95