Programming Guide | VLT® AutomationDrive FC 301/FC 302
Setup:
2 setups
Data type:
Uint16
33-16 Marker Number for Slave
Default value:
1
Setup:
2 setups
Data type:
Uint16
33-17 Master Marker Distance
Default value:
4096
Setup:
2 setups
Data type:
Uint32
33-18 Slave Marker Distance
Default value:
4096
Setup:
2 setups
Data type:
Uint32
33-19 Master Marker Type
Default value:
[0] Encoder Z positive
Setup:
2 setups
Data type:
Uint8
Option
Name
[0]*
Encoder Z positive
[1]
Encoder Z negative
[2]
Ext. marker positive
[3]
Ext. marker negative
33-20 Slave Marker Type
Default value:
[0] Encoder Z positive
Setup:
2 setups
Data type:
Uint8
672
| © 2024.09
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Parameter Descriptions
0
True
Range, 1 - 10000
0
True
Range, 0 - 1073741823
0
True
Range, 0 - 1073741823
0
True
Option, Array [4]
–
True
Option
–
True
AU275636650261en-003201 / 130R0334
Need help?
Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?