Programming Guide | VLT® AutomationDrive FC 301/FC 302
Setup:
All setups
Data type:
VisStr[18]
Shows the software version of the installed option.
43-1* Power Card Status
6.38.3
The following parameters are only available in FC 302:
Parameter 43-00 Component Temp.
l
Parameter 43-01 Auxiliary Temp.
l
This parameter group contains read-only information on hardware components in the power section. All parameters in this group are
arrays:
[0]: Power card 1 (the master power card in a parallel drive, or the only power card in a drive with a single inverter section).
l
[1]: Power card 2 (inverter connection in a parallel drive).
l
[2]: Power card 3 (inverter connection in a parallel drive).
l
[3]: Power card 4 (inverter connection in a parallel drive).
l
[4]: Power card 5 (rectifier connection in a parallel drive).
l
[5]: Power card 6 (rectifier connection in a parallel drive).
l
[6]: Power card 7 (rectifier connection in a parallel drive).
l
[7]: Power card 8 (rectifier connection in a parallel drive).
l
43-10 HS Temp. ph.U
Default value:
0 °C
Setup:
All setups
Data type:
Int8
Shows the heat sink temperature at the location of the phase U IGBT power module. This measurement is not available in all enclosure
sizes. Parameter 16-34 Heatsink Temp. uses the value in this parameter.
43-11 HS Temp. ph.V
Default value:
0 °C
Setup:
All setups
Data type:
Int8
Shows the heat sink temperature at the location of the phase V IGBT power module. This measurement is not available in all enclosure
sizes. Parameter 16-34 Heatsink Temp. uses the value in this parameter.
43-12 HS Temp. ph.W
Default value:
0 °C
Setup:
All setups
Data type:
Int8
© 2024.09
Conversion index:
Change during operation:
  NOTICE
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter Descriptions
0
True
Range, -128 - 127, Array [8]
100
True
Range, -128 - 127, Array [8]
100
True
Range, -128 - 127, Array [8]
100
True
AU275636650261en-003201 / 130R0334 |