Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I
[9]
Above I
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
© 2024.09
low
high
Description
Select the boolean (true or false) input to activate smart logic
control. Enters the fixed value False.
Enters the fixed value True.
The motor runs.
The motor runs within the programmed current and speed
ranges set in parameter 4-50 Warning Current Low to parameter
4-53 Warning Speed High.
The motor runs on reference.
The torque limit set in parameter 4-16 Torque Limit Motor Mode
or parameter 4-17 Torque Limit Generator Mode is exceeded.
The motor current limit set in parameter 4-18 Current Limit is
exceeded.
The motor current is outside the range set in parameter 4-18
Current Limit.
The motor current is lower than set in parameter 4-50 Warning
Current Low.
The motor current is higher than set in parameter 4-51 Warning
Current High.
The speed is outside the range set in parameter 4-52 Warning
Speed Low and parameter 4-53 Warning Speed High.
The output speed is lower than the setting in parameter 4-52
Warning Speed Low.
The output speed is higher than the setting in parameter 4-53
Warning Speed High.
The feedback is outside the range set in parameter 4-56 Warning
Feedback Low and parameter 4-57 Warning Feedback High.
The feedback is below the limit set in parameter 4-56 Warning
Feedback Low.
The feedback is above the limit set in parameter 4-57 Warning
Feedback High.
The thermal warning turns on when the temperature exceeds
the limit in the motor, the drive, the brake resistor, or the
thermistor.
The mains voltage is outside the specified voltage range.
The output is high when the drive is running counterclockwise
(the logical product of the status bits running AND reverse).
A warning is active.
A (trip) alarm is active.
A (trip lock) alarm is active.
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
419