Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[10]
Select preset ref 0
[11]
Select preset ref 1
[12]
Select preset ref 2
[13]
Select preset ref 3
[14]
Select preset ref 4
[15]
Select preset ref 5
[16]
Select preset ref 6
[17]
Select preset ref 7
[18]
Select ramp 1
[19]
Select ramp 2
[20]
Select ramp 3
[21]
Select ramp 4
[22]
Run
[23]
Run reverse
[24]
Stop
[25]
Qstop
[26]
Dcstop
[27]
Coast
[28]
Freeze output
[29]
Start timer 0
[30]
Start timer 1
© 2024.09
Description
Selects preset reference 0. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 1. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 2. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 3. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 4. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 5. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 6. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects preset reference 7. If the active preset reference is
changed, it merges with other preset reference commands
coming from either the digital inputs or via a fieldbus.
Selects ramp 1.
Selects ramp 2.
Selects ramp 3.
Selects ramp 4.
Issues a start command to the drive.
Issues a start reverse command to the drive.
Issues a stop command to the drive.
Issues a quick stop command to the drive.
Issues a DC stop command to the drive.
The drive coasts immediately. All stop commands including the
coast command stop the SLC.
Freezes the output frequency of the drive.
Starts timer 0, see parameter 13-20 SL Controller Timer for
further description.
Starts timer 1, see parameter 13-20 SL Controller Timer for
further description.
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
493

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents

Save PDF